What tests are required to list a lamp-ballast platform on the Certified Lighting Subcomponent Database (CSD) so that it can be used to certify a product to the Luminaires specification? Follow

To list a lamp-ballast platform on the Certified Lighting Subcomponent Database (CSD), data must be submitted to a certification body (CB) demonstrating the lamp-ballast platform's compliance with the following specification requirements: Luminous Efficacy Lumen Output Light Source Life Lumen Maintenance Correlated Color Temperature (Indoor and Indoor/Outdoor only) Color Rendering (Indoor and Indoor/Outdoor only) Source Start Time (Indoor and Indoor/Outdoor only) Source Run-Up Time (Indoor and Indoor/Outdoor only) Dimming (as applicable) Power Factor Transient Protection Lamp Current Crest Factor Operating Frequency Maximum Recommended Ballast Case Temperature Ballast Hot Spot Location Minimum Operating Temperature (Outdoor and Indoor/Outdoor only) Electronic Ballast Safety